• Title of article

    Accurate estimation of the fisher information matrix for the PET image reconstruction problem

  • Author/Authors

    E.، Asma, نويسنده , , R.M.، Leahy, نويسنده , , Li، Quanzheng نويسنده , , Qi، Jinyi نويسنده , , J.R.، Bading, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    -1056
  • From page
    1057
  • To page
    0
  • Abstract
    The Fisher information matrix (FIM) plays a key role in the analysis and applications of statistical image reconstruction methods based on Poisson data models. The elements of the FIM are a function of the reciprocal of the mean values of sinogram elements. Conventional plug-in FIM estimation methods do not work well at low counts, where the FIM estimate is highly sensitive to the reciprocal mean estimates at individual detector pairs. A generalized error look-up table (GELT) method is developed to estimate the reciprocal of the mean of the sinogram data. This approach is also extended to randoms precorrected data. Based on these techniques, an accurate FIM estimate is obtained for both Poisson and randoms precorrected data. As an application, the new GELT method is used to improve resolution uniformity and achieve nearuniform image resolution in low count situations.
  • Keywords
    Hydrograph
  • Journal title
    IEEE Transactions on Medical Imaging
  • Serial Year
    2004
  • Journal title
    IEEE Transactions on Medical Imaging
  • Record number

    100906