• Title of article

    The sterilization of Escherichia coli by dielectric-barrier discharge plasma at atmospheric pressure

  • Author/Authors

    Hu Miao، نويسنده , , Guo Yun، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    6
  • From page
    7065
  • To page
    7070
  • Abstract
    The sterilization of E. coli (ATCC8099) using an atmospheric pressure, air DBD plasma driven by 100 Hz high-voltage power supply was investigated in this paper. The results showed that germicidal efficiency was closely related to the plasma treatment time, the gap spacing, the initial cell density and the surface characters of substrate materials. The germicidal efficiency was 99.999% under the conditions of 5-min plasma treatment, 3-cm gap spacing and on PET films. After plasma exposure for 5 min, the temperature was observed below 43 °C which could not lead to inactivate E. coli. The observation of protein leakage and cell morphology alteration by transmission electron microscopy (TEM) techniques revealed that the etching action on cell membrane by electrons, ions and radicals was primary reason of DBD air plasma sterilization.
  • Keywords
    Plasma , DBD , Escherichia coli , Sterilization
  • Journal title
    Applied Surface Science
  • Serial Year
    2011
  • Journal title
    Applied Surface Science
  • Record number