Title of article
A test method to evaluate the thermal performance of window glazings
Author/Authors
G. Alvarez، نويسنده , , M.J. Palacios، نويسنده , , J.J. Flores، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
10
From page
803
To page
812
Abstract
An apparatus and a methodology to evaluate the thermal performance of window glazing are presented. Single glazings commercially available in Mexico are currently tested. During the test sequence, the glass samples are mounted in a specially designed calorimeter apparatus. The test is conducted in controlled laboratory conditions at the National Centre for Research and Technology Development in Mexico using a solar simulator test lamp. The calorimeter apparatus and the solar simulator test lamp were characterised and the overall heat loss coefficient Uc measured was of 1.7±0.1 W/m2°C. Overall heat transfer and shading coefficients are derived from the experimental results. The test method described allows the testing of practically any kind of glazing array. Glasses under investigation were of the reflective, absorbing coloured and common ones. This test method can be adequate to evaluate film coating glazing or multiple solar control coating glazing. Also, it can be of assistance to researchers, glass manufacturers and building designers in the development of rating and comparing of glazing options.
Keywords
Thermal performance , Buildings , Comparative test data , Glazing