Title of article
Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators
Author/Authors
B. Tashtoush، نويسنده , , M. Tahat، نويسنده , , M.A. Shudeifat، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
12
From page
495
To page
506
Abstract
An experimental study on the replacement of R12 in domestic refrigerators by new hydrocarbon/hydrofluorocarbon refrigerant mixtures has been carried out. Parameters and factors, affecting the performance characteristics of these refrigerants, based on experimental data have been compared to those of R12. The results show that butane/propane/R134a mixtures provide excellent performance parameters, such as coefficient of performance of refrigerator, compression power, volumetric efficiency, condenser duty, compressor discharge pressure and temperature, relative to a 210 g charge of R12. In addition, the results support the possibility of using butane/propane/R134a mixtures as an alternative to R12 in domestic refrigerators, without the necessity of changing the compressor lubricating oil used with R12.
Keywords
Propane/butane mixtures , Domestic refrigeration , Refrigerants
Journal title
Applied Thermal Engineering
Serial Year
2002
Journal title
Applied Thermal Engineering
Record number
1023448