• Title of article

    Electrocatalytic Determination of Hydrazine using Glassy Carbon Electrode with Calmagates

  • Author/Authors

    Mazloum-Ardakani ، Mohammad نويسنده Department of Chemistry, Faculty of Science, Yazd University, Yazd, I.R. Iran , , Sadeghiane، Ali نويسنده Department of Chemistry, Payam Noor University, Ardakan Center, Ardakan, Iran , , Moosavizadeh، Seyed Hossein نويسنده Department of Chemistry, Faculty of Science, Payam Noor University, Sirjan Center, Sirjan, Iran , , Karimi، Mohammad Ali نويسنده , , Mashhadizadeh، Mohammad Hossein نويسنده Department of Chemistry, Tarbiat Moallem University of Tehran, Tehran, I.R. Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی سال 2009
  • Pages
    15
  • From page
    224
  • To page
    238
  • Abstract
    Voltammetric methods were used for the determination of hydrazine and investigation of its electrochemical behavior on a glassy carbon electrode in the presence of calmagite as a homogeneous mediator. The key factors considered in the optimization process were pH, mediator concentration and scan rate. The results showed with optimizing pH, mediator concentration and scan rate, the convenient selectivity of potential and current of hydrazine oxidation can be achieved. Calmagite as a mediator can catalyze the hydrazine oxidation in an aqueous buffer solution (pH=8.0). The apparent catalytic rate constant, k and diffusion coefficient, D of hydrazine were obtained as (1.2×104 M-1s-1) and (4.23×10-5cm2 s-1), respectively. The calibration curve was linear in the rang of 10.0 – 800.0 ?M hydrazine, and the detection limit was 5.3 ?M by linear sweep voltammetry, also differential pulse voltammetric determination of hydrazine exhibits two linear range of 1.0-20.0 and 40.0-800.0 ?M and detection limit was 0.8 ?M.
  • Journal title
    Analytical and Bioanalytical Electrochemistry
  • Serial Year
    2009
  • Journal title
    Analytical and Bioanalytical Electrochemistry
  • Record number

    1025624