Title of article
X-ray fluorescence analysis for the determination of potassium in small quantities of silicate minerals for K–Ar dating Original Research Article
Author/Authors
Jesus Sole، نويسنده , , Pere Enrique، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
7
From page
199
To page
205
Abstract
X-ray fluorescence analyses were used to determine the potassium contents of silicate minerals with K2O concentrations between 1 and 13 wt.%. This method is based on lithium tetraborate fused glass discs with 50 mg of sample at ∼1:120 dilution. The results show that this high-dilution minimises matrix effects and that both precision and accuracy are below 1.5% for all the silicate minerals analysed, whatever their composition. This analytical procedure is useful for K determination in small samples of mineral separates needed to establish K–Ar geochronology, without using acid digestion.
Journal title
Analytica Chimica Acta
Serial Year
2001
Journal title
Analytica Chimica Acta
Record number
1032536
Link To Document