• Title of article

    Precise determination of manganese in steel by dc glow discharge optical emission spectrometry associated with voltage modulation technique Original Research Article

  • Author/Authors

    Kazuaki Wagatsuma، نويسنده , , Kenji Kodama، نويسنده , , Hyunkook Park، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    7
  • From page
    257
  • To page
    263
  • Abstract
    A voltage modulation technique was applied for the precise and accurate determination of manganese in steels in dc glow discharge optical emission spectrometry. Emission signals from the glow discharge plasma are modulated by a cyclic variation of the discharge voltage so that only the desired signals can be detected at very low noise levels by using a lock-in amplifier. Mn determination in low-alloyed steels was performed to estimate the repeatability of the analytical result. For each measurement, the relative standard deviation (R.S.D.) of the intensities of the Mn I 403.08-nm line was ca 0.1% when a steel sample containing 0.329 mass% Mn was employed. Averaging all analytical values, which are obtained in various discharge conditions, yields statistical information on the precision and accuracy of the analytical values obtained. The relative error from the recommended value is calculated to be 0.5%. The R.S.D. over the analytical values is 1.5%, representing the overall analytical performance of this technique.
  • Keywords
    Precision , Glow discharge optical emission spectrometry , Repeatability , manganese , Steel , Voltage modulation
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2004
  • Journal title
    Analytica Chimica Acta
  • Record number