Title of article
Determination of trace amounts of manganese in natural waters by flow injection stopped-flow catalytic kinetic spectrophotometry Original Research Article
Author/Authors
Ling Su، نويسنده , , Jianguo Li، نويسنده , , Hongbing Ma، نويسنده , , Guanhong Tao، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
8
From page
281
To page
288
Abstract
Trace amounts of manganese were analyzed by flow injection catalytic kinetic spectrophotometry, based upon the catalytic effects of Mn(II) on the redox reaction between sodium periodate and 4,4′-bis(dimethylamino)-diphenylmethane. The reaction could occur rapidly at room temperature in the presence of nitriloacetic acid at pH 5.4. The measurements were conducted at 602 nm of an unstable intermediate blue product of the reaction, which greatly increased the sample throughput. Flow injection technique was utilized to precisely control the timing of merging and reaction of the sample and reagents. A stopped-flow approach was used to improve the sensitivity of the system. A detection limit (3σ) of 0.073 μg l−1 was achieved at a sampling frequency of 60 h−1. The relative standard deviation was 0.5% for the determination of 10 μg l−1 Mn (n = 11). The proposed method was validated by the analysis of an estuarine water reference material, SLEW-2 and successfully applied to the analyses of several natural waters.
Keywords
Catalytic kinetic spectrophotometry , Flow injection analysis , 4?-Bis(dimethylamino)-diphenylmethane , 4 , Natural waters , manganese
Journal title
Analytica Chimica Acta
Serial Year
2004
Journal title
Analytica Chimica Acta
Record number
1034323
Link To Document