• Title of article

    Improved method for the determination of kynurenic acid in rat plasma by column-switching HPLC with post-column fluorescence detection Original Research Article

  • Author/Authors

    Shogo Mitsuhashi، نويسنده , , Takeshi Fukushima، نويسنده , , Junko Kawai، نويسنده , , Masayuki Tomiya، نويسنده , , Tomofumi Santa، نويسنده , , Kazuhiro Imai، نويسنده , , Toshimasa Toyo’oka، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    8
  • From page
    36
  • To page
    43
  • Abstract
    Kynurenic acid (KYNA), an endogenous antagonist of ionotropic glutamate and α7 nicotinic receptors, was fluorometrically determined by column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. The HPLC system consists of two octadecyl silica (ODS) columns, both of which are connected with an anion-exchange column (trapping column). Following sample injection onto the HPLC column, KYNA was separated on the first ODS column with a mobile phase of H2O/acetonitrile (95/5) containing 0.1% acetic acid. The peak fraction of KYNA was trapped on the anion-exchange column by changing the position of a six-port valve and then introduced into the second ODS column. Subsequently, KYNA was detected fluorometrically as a fluorescence complex formed with zinc ion which was pumped constantly. Instrumental limit of detection was approximately 0.16 nM, which corresponded to 8.0 fmol (per 50 μl injection, signal to noise ratio 3), and the limit of quantification was 0.53 nM (signal to noise ratio 10). Intra- and inter-day relative standard deviations were 1.1–3.9% (n = 3) and 3.0–5.3% (n = 3), respectively. The peak of KYNA in rat plasma was clearly detected by the proposed column-switching HPLC system after a facile pretreatment procedure. Intra- and inter-day relative mean errors were −1.6–1.4% (n = 3) and −2.4 to −0.4% (n = 3), respectively, with a satisfactory precision (within 5.0%). A calibration curve for the determination of KYNA showed a good linearity (r2 > 0.999) in the range of 25–200 nM. The KYNA concentrations in the plasma of male Sprague-Dawley rats (8-week-old) were 44 ± 5.5 nM (mean ± S.E., n = 5). In ketamine-treated rats, which are animal models of schizophrenia, the plasma KYNA concentrations were significantly increased compared with those in the control rats (p < 0.05).
  • Keywords
    Kynurenic acid , Column-switching HPLC , Ketamine , Schizophrenia , Fluorometric detection
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2006
  • Journal title
    Analytica Chimica Acta
  • Record number

    1035712