• Title of article

    Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques Original Research Article

  • Author/Authors

    Guillermo Grindlay، نويسنده , , Juan Mora، نويسنده , , Salvador Maestre، نويسنده , , Luis Gras، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    14
  • From page
    24
  • To page
    37
  • Abstract
    Elemental wine analysis is often required from a nutritional, toxicological, origin and authenticity point of view. Inductively coupled plasma based techniques are usually employed for this analysis because of their multi-elemental capabilities and good limits of detection. However, the accurate analysis of wine samples strongly depends on their matrix composition (i.e. salts, ethanol, organic acids) since they lead to both spectral and non-spectral interferences. To mitigate ethanol (up to 10% w/w) related matrix effects in inductively coupled plasma atomic emission spectrometry (ICP-AES), a microwave-based desolvation system (MWDS) can be successfully employed. This finding suggests that the MWDS could be employed for elemental wine analysis. The goal of this work is to evaluate the applicability of the MWDS for elemental wine analysis in ICP-AES and inductively coupled plasma mass spectrometry (ICP-MS). For the sake of comparison a conventional sample introduction system (i.e. pneumatic nebulizer attached to a spray chamber) was employed. Matrix effects, precision, accuracy and analysis throughput have been selected as comparison criteria. For ICP-AES measurements, wine samples can be directly analyzed without any sample treatment (i.e. sample dilution or digestion) using pure aqueous standards although internal standardization (IS) (i.e. Sc) is required. The behaviour of the MWDS operating with organic solutions in ICP-MS has been characterized for the first time. In this technique the MWDS has shown its efficiency to mitigate ethanol related matrix effects up to concentrations of 1% (w/w). Therefore, wine samples must be diluted to reduce the ethanol concentration up to this value. The results obtained have shown that the MWDS is a powerful device for the elemental analysis of wine samples in both ICP-AES and ICP-MS. In general, the MWDS has some attractive advantages for elemental wine analysis when compared to a conventional sample introduction system such as: (i) higher detection capabilities; (ii) lower ethanol matrix effects; and (iii) lower spectral interferences (i.e. ArC+) in ICP-MS.
  • Keywords
    Desolvation system , Atomic emission spectrometry , mass spectrometry , Inductively coupled plasma , Microwave , Wine
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2008
  • Journal title
    Analytica Chimica Acta
  • Record number

    1036585