• Title of article

    Analysis of ergosterol for the detection of mold in soils by automated on-fiber derivatization headspace extraction–SPME-GC/MS Original Research Article

  • Author/Authors

    D.-R. Parkinson، نويسنده , , J.M. Warren، نويسنده , , J. Pawliszyn، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    7
  • From page
    181
  • To page
    187
  • Abstract
    The estimate of ergosterol ([5,7,22-ergostatrien-3β-ol] has been used by many to relate its concentration to the amount of mold in soils. This new method using on-fiber derivatization–solid phase microextraction-GC/MS method for the analysis of ergosterol presents a quick and straightforward method where low detection limits (1.5 ppb) and good limit of quantitation range (3 ppb to 90 ppm) can be achieved with careful control of analytical parameters. After saponification of real soil samples, sampling without extensive workup can be performed and analysis by a standard addition method can be utilized to deduce the original sample concentration of ergosterol. Peak area extraction analysis by MS SIM on selected characteristic fragment ions gives results with RSD ≤ 2.2%.
  • Keywords
    Ergosterol , Derivatization , Method development , Solid phase microextraction-gas chromatography/mass spectrometry , Soil
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2010
  • Journal title
    Analytica Chimica Acta
  • Record number