• Title of article

    First and second law analysis of pulse tube refrigerator

  • Author/Authors

    Ya-Ling HeCorresponding author contact information، نويسنده , , E-mail the corresponding author، نويسنده , , Jing Huang، نويسنده , , Chunfeng Zhao، نويسنده , , Ying-Wen Liu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    7
  • From page
    2301
  • To page
    2307
  • Abstract
    The first and second law of thermodynamics was used to analyze the orifice type and the double-inlet type of pulse tube refrigerator (PTR). Detailed dynamic characteristics of the thermodynamics, flow and heat transfer processes in the PTR were revealed, including the dynamic pressure variations, transient gas temperature, mass flow rate in the PTR. The exergy loss method was used to analyze each component in the PTR for the first time, and the performance coefficients of all components of PTR have been obtained. It was found that the performance coefficient of the double-inlet PTR was 0.108, 9% higher than that of the orifice PTR. The analysis also showed that the exergy efficiency of the double-inlet PTR was 29.95%, significantly higher than that of the orifice PTR (25.04%). In addition, it was found that the exergy losses in the regenerator and orifice were substantially larger than in other components of the PTR system. The optimal design of these two key components is, therefore, essential for the further improvement of the PTR performance.
  • Keywords
    Numerical simulation , Thermodynamics analysis , Exergy losses , Pulse tube refrigerator
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2006
  • Journal title
    Applied Thermal Engineering
  • Record number