• Title of article

    Steady state operation of a copper–water LHP with a flat-oval evaporator

  • Author/Authors

    S. Becker، نويسنده , , S. Vershinin، نويسنده , , V. Sartre، نويسنده , , E. Laurien، نويسنده , , J. Bonjour، نويسنده , , Yu.F. Maydanik، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    10
  • From page
    686
  • To page
    695
  • Abstract
    In order to dissipate the heat generated by electronic boxes in avionic systems, a copper–water LHP with a flat-oval evaporator was fabricated and tested at steady state. The LHP consists of a flat shaped evaporator, 7 mm thick, including compensation chamber with attached heat exchanger. The condenser is cooled by forced convection of liquid. The variable parameters are the heat sink and ambient temperatures (20 and 55 °C), the orientation (−90° to +90° in two perpendicular planes) and the power input (0–100 W). Evaporator wall temperatures are higher when the evaporator is placed above the condenser. For heat sink and ambient temperature of 20 °C the evaporator wall temperature does not vary much with heat load for all measured elevations. But it fluctuates at heat sink and ambient temperature equal to 55 °C when the evaporator is placed below the condenser. The LHP total thermal resistance is governed by the condenser resistance. It decreases with increasing heat load, whatever the operating conditions, because the part of the condenser internal surface area used for condensation increases too. A minimum thermal resistance of 0.2 K/W was obtained. The maximum thermal resistance was 2.7 K/W.
  • Keywords
    Heat sink temperature effect , Tilt angle effect , Heat transfer , Experimental study , Avionic application , Loop heat pipe
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2011
  • Journal title
    Applied Thermal Engineering
  • Record number