Title of article
Investigation of impact of different working fluids on the operational characteristics of miniature LHP with flat evaporator
Author/Authors
Zhichun Liu، نويسنده , , Dongxing Gai، نويسنده , , Huan Li، نويسنده , , Wei Liu، نويسنده , , Jinguo Yang، نويسنده , , Mengmeng Liu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
3387
To page
3392
Abstract
Experimental studies are carried out on the operational characteristic of LHP with a flat evaporator, the difference between methanol and acetone as working fluid is especially investigated in the study. Result shows that the flat-plate LHP has a good startup characteristic and ability to adapt heat load change. Compared with LHP-methanol, the LHP-acetone starts up faster, and when it comes to steady status, the temperature of evaporator wall is lower; however, heat transfer limitation of LHP-acetone is far less than that of LHP-methanol.
Keywords
LHP , Working fluid , Temperature oscillations
Journal title
Applied Thermal Engineering
Serial Year
2011
Journal title
Applied Thermal Engineering
Record number
1045759
Link To Document