• Title of article

    Analysis and design of a robust average current mode control loop for parallel buck DC-DC converters to reduce line and load disturbance

  • Author/Authors

    G.، Garcera, نويسنده , , M.، Pascual, نويسنده , , E.، Figueres, نويسنده , , J.M.، Benavent, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    11
  • From page
    414
  • To page
    424
  • Abstract
    A robust control scheme for multi-module parallel buck DC-DC converters with average current mode control (ACC) is presented. The proposed loop adds an inner loop to the conventional current and voltage ACC loops, reducing the sensitivity of the outer voltage loop to the changing power stage parameters: number of modules, input voltage, load and component tolerances. The loop improves significantly the disturbance rejection of the converter, i.e. the closed loop output impedance and audiosusceptibility, while preserving the stability and the loop gain crossover frequency to a significant extent. The performance of the proposed scheme is demonstrated by both small-signal and large signal experimental results.
  • Keywords
    Distributed systems
  • Journal title
    IEE Proceedings Electric Power Applications
  • Serial Year
    2004
  • Journal title
    IEE Proceedings Electric Power Applications
  • Record number

    106633