Title of article
The effects of ultrasonic peening treatment on the ultra-long life fatigue behavior of welded joints
Author/Authors
Danqing Yin، نويسنده , , Dongpo Wang، نويسنده , , Hongyang Jing، نويسنده , , Lixing Huo، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2010
Pages
9
From page
3299
To page
3307
Abstract
The conventional fatigue design codes was formulated based on the data from test stress cycles less than 1 × 107. Most of them could not be applied for welded structures serviced in the ultra-long life region so the new recommendations were discussed. The method of ultrasonic peening treatment (UPT) was introduced in this thesis as a post-weld treatment to improve the fatigue strength of the welded structures. The fatigue behavior of welded structures in the ultra-long life region was investigated using an ultrasonic fatigue test machine under two post-weld treatment states: the as-welded and the UPT. Discussion had also been made about the fracture mechanism on the UPT joints in ultra-long life fatigue test.
Keywords
C. Ultrasonic peening treatment , E. Ultra-long life fatigue design , H. Fractography
Journal title
Materials and Design
Serial Year
2010
Journal title
Materials and Design
Record number
1069021
Link To Document