Title of article
CHF characteristics of R-134a flowing upward in uniformly heated vertical tube
Author/Authors
Chang Ho Kim، نويسنده , , Soon Heung Chang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
8
From page
2242
To page
2249
Abstract
An experimental study of the critical heat flux (CHF) using R-134a in uniformly heated vertical tube was performed and 182 CHF data points were obtained from the present work to investigate the CHF characteristics of R-134a. The investigated flow parameters in R-134a were: (1) outlet pressures of 13, 16.5, 23.9 bar, (2) mass fluxes of 285–1300 kg/m2 s, (3) subcooling temperatures of 5–40 °C. The CHF tests were performed in a 17.04 mm I.D. test section with heated length of 3 m. The parametric trends of CHF show a general agreement with previous understanding in the water. To assess the suitability of the CHF test using R-134a for modeling the CHF in water, Bowring correlation and Katto correlation were used in the present investigation. It was found that the present test results coincided well with the data predicted with both correlations. It demonstrates that the R-134a can be used as the CHF modeling fluid of water for the investigated flow conditions and geometric condition.
Keywords
CHF , CHF correlation , Fluid-to-fluid model , R-134a , Forced convective boiling
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2005
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1072091
Link To Document