• Title of article

    Electrohydrodynamic enhancement of in-tube convective condensation heat transfer

  • Author/Authors

    H. Sadek، نويسنده , , A.J. Robinson، نويسنده , , J.S. Cotton، نويسنده , , C.Y. Ching، نويسنده , , M. Shoukri، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    11
  • From page
    1647
  • To page
    1657
  • Abstract
    An experimental investigation of electrohydrodynamic (EHD) augmentation of heat transfer for in-tube condensation of flowing refrigerant HFC-134a has been performed in a horizontal, single-pass, counter-current heat exchanger with a rod electrode placed in the centre of the tube. The effects of varying the mass flux (55 kg/m2 s ⩽ G ⩽ 263 kg/m2 s), inlet quality (0.2 ⩽ xin ⩽ 0.83) and the level of applied voltage (0 kV ⩽ V ⩽ 8 kV) are examined. The heat transfer coefficient was enhanced by a factor up to 3.2 times for applied voltage of 8 kV. The pressure drop was increased by a factor 1.5 at the same conditions of the maximum heat transfer enhancement. The improved heat transfer performance and pressure drop penalty are due to flow regime transition from stratified flow to annular flow as has been deduced from the surface temperature profiles along the top and bottom surfaces of the tube.
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2006
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number