Title of article
Comparison of the CHF data for water and refrigerant HFC-134a by using the fluid-to-fluid modeling methods
Author/Authors
Se-Young Chun، نويسنده , , Sung-Deok Hong، نويسنده , , Yeon-Sik Cho، نويسنده , , Won Pil Baek، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
11
From page
4446
To page
4456
Abstract
CHF experiments in tubes and annulus cooled with HFC-134a have been performed. The HFC-134a and water CHF data have been compared by applying the Ahmad and the Katto modeling parameters. For the mass fluxes from 710 to 3500 kg m−2 s−1 in the tubes, the HFC-134a and water CHF data fall close to the same curve on the plane of the dimensionless CHF vs. the Ahmad and the Katto modeling parameters. For the mass fluxes below 600 kg m−2 s−1 in an annulus, the dimensionless CHFs as a function of the Ahmad and the Katto modeling parameters show a large difference between the HFC-134a and the water. The Katto and the Ahmad modeling parameters cannot be correlated with the dimensionless CHF data for HFC-134a and water on the same curve in the low mass flux and high quality conditions.
Keywords
Tubes , Annulus , HFC-134a , Critical heat flux , Fluid-to-fluid modeling , Low flow rate