Title of article
A complex but accurate correlation for predicting critical heat flux in a round tube for low and medium pressures under circumferentially non-uniform heating conditions
Author/Authors
A. Olekhnovitch، نويسنده , , J. Sun، نويسنده , , A. Teyssedou، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
14
From page
2041
To page
2054
Abstract
This paper presents an empirical correlation for predicting the critical heat flux (CHF) of vertical, upward, steam–water flows in round tubes for low and medium pressures under circumferentially non-uniform heating conditions. This correlation is based on experiments carried out with test sections having an inner diameter of 22 mm and heated lengths ranging from 1.8 to 3.5 m. The ratios between the maximum and the minimum heat fluxes were 1.0, 4.7 and 8.3. The experiments were carried out for outlet pressures and mass fluxes ranging from 10 to 40 bar and 300 to 1600 kg m−2 s−1, respectively. The root mean square error of predicted CHF values by using the proposed correlation and applying the heat balance method is 3.7%.
Keywords
Non-uniformly heated tube , Boiling flow , Critical heat flux , Empirical correlation
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2008
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1075357