• Title of article

    Pool boiling heat transfer in a vertical annulus as the bottom inflow area changes

  • Author/Authors

    Myeong-Gie Kang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    3369
  • To page
    3377
  • Abstract
    To identify effects of the bottom inflow area on pool boiling heat transfer in a vertical annulus, three tube diameters (16.5, 25.4, 34.0 mm) and the saturated water at atmospheric pressure has been tested. The inflow area has been changed from 0 to 1060.3 mm2. To clarify effects of the inflow area on heat transfer results of the annulus are compared to the data of a single unrestricted tube. The inflow area changes heat transfer coefficients much and moves the deterioration point of heat transfer coefficients to the higher heat fluxes. To quantify effects of the inflow area on heat transfer, a new empirical correlation has been developed in terms of the area ratio, inflow area, and the heat flux. The correlation predicts the heat transfer data of boiling within ±10%.
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2008
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number

    1075471