Title of article
The effects of PE additive on the performance of polystyrene vacuum insulation panels
Author/Authors
P.C. Tseng، نويسنده , , H.S. Chu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
7
From page
3084
To page
3090
Abstract
The effects of adding polyethylene (PE) in polystyrene (PS) foaming material on the cell structure and the heat transfer of vacuum insulation panels (VIPs) are examined in this study. Several parameters are proposed to describe the foam structure, namely, the broken cell ratio, the average cell size and the solid volume fraction. Adding 2% PE was effective in altering the cell structure and reducing the heat transfer, while adding 5% PE did not improve the performance further. The lowest thermal conductivity found in this study is 4.4 mW m−1 K−1, which is among the best published performances of VIP.
Keywords
Broken cell ratio , Solid volume fraction , PS foam insulation
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2009
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1076084
Link To Document