Title of article
Mechanical vapor compression desalination systems — A case study Original Research Article
Author/Authors
Narmine H. Aly، نويسنده , , Adel K. El-Figi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
8
From page
143
To page
150
Abstract
The thermal performance of the mechanical vapor compression (MVC) system was investigated. This work describes the mathematical and experimental study of the MVC system. The unit, with a capacity of 5 m3/d, is currently located in the heat transfer laboratory of the Atomic Energy Authority of Egypt. Some details of the operational features of the unit are presented, including a comparison of the data of the unit with both theoretical and experimental results. In the modeling, the overall mass and energy balance equations are given. The experimental and theoretical results indicated that the production rate increases by increasing the operating temperature from 70°C to about 98°C, “evaporator designed temperature70°C”. Also, increasing the evaporator temperature has a good effect on the heat transfer coefficient.
Keywords
Heat transfer coefficient , Desalination , MVC