• Title of article

    Degradation of obsolete DDT by Fenton oxidation with zero-valent iron Original Research Article

  • Author/Authors

    R. Boussahel، نويسنده , , D. Harik، نويسنده , , M. Mammar، نويسنده , , S. Lamara-Mohamed، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    369
  • To page
    372
  • Abstract
    We report in this paper the preliminary results obtained during degradation tests of obsolete DDT by Fenton oxidation with zero-valent iron. Iron powder, treated beforehand by a solution of H2SO4, was introduced into a glass engine containing a solution of distilled water doped by known quantities of obsolete pesticide and hydrogen peroxide. A continuous mechanical agitation was then applied and samples were taken regularly. The pesticides were extracted by liquid–liquid extraction with hexane and analyzed by a HPLC provided with a UV-visible detector. The results obtained show that the degradation reaction of the DDT is pseudo first-order kinetic which depends on the quantity of iron and pH. The acids, pH largely improve its speed; Fenton oxidation using zero-valent iron as catalytic source of ferro-iron very clearly improves the rate of the DDT degradation; 2,4-DDT is degraded quicker than 4,4-DDT. Fenton oxidation of the DDT provides a promising alternative to the traditional techniques of elimination aslo from the economic point of view.
  • Keywords
    Fenton reaction , DDT , Treatment , remediation , Iron , Obsolete pesticide
  • Journal title
    Desalination
  • Serial Year
    2007
  • Journal title
    Desalination
  • Record number

    1110777