Title of article
A new mixed mode fracture test specimen covering positive and negative values of T-stress
Author/Authors
Mirsayar ، M.M. نويسنده ,
Issue Information
فصلنامه با شماره پیاپی 6 سال 2014
Pages
6
From page
67
To page
72
Abstract
A new fracture test specimen is suggested and analyzed using finite element method. The mode I and mode II stress intensity factors as well as the T-stress were calculated for three geometries and loading conditions. It is shown that the specimen, called single edge cracked ring (SECR), covers different mixed mode loading conditions from pure mode I to pure mode II. The SECR specimen also covers negative and positive values of T-stresses. From the practical view point, the suggested specimen can be used easily for mixed mode II fracture tests.
Journal title
Engineering Solid Mechanics
Serial Year
2014
Journal title
Engineering Solid Mechanics
Record number
1114338
Link To Document