• Title of article

    Membrane autopsy of a 10 year old hollow fibre membrane from Sydney Olympic Park water reclamation plant Original Research Article

  • Author/Authors

    S. Phuntsho، نويسنده , , A. Listowski، نويسنده , , H.K. Shon، نويسنده , , P. Le-Clech، نويسنده , , S. Vigneswaran، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    241
  • To page
    247
  • Abstract
    Membrane autopsy was performed for a 10 year old polypropylene (PP) hollow fibre microfiltration membrane from Sydney Olympic Park water reclamation plant. The properties of the membrane were studied using scanning electron microscope (SEM) imaging, contact angle, bubble test, thermogravimetric analysis, tensile strength test and functional group. The old and fouled membrane exhibited a significant difference in surface properties and material strength in comparison to the virgin membrane. The old and fouled membrane surface is less hydrophilic and less negatively charged indicating that aged membrane is more vulnerable to fouling than virgin membrane. The fibre material of the old fouled membrane appears less flexible and brittle. Foulant analysis indicated that major components of the metallic elements were silicon and calcium. The dissolved organic matter was mainly composed of biopolymers (hydrophilic) and humic substances (hydrophobic).
  • Keywords
    Membrane fouling , Membrane autopsy , Organic and inorganic foulant , Hollow fibre membrane
  • Journal title
    Desalination
  • Serial Year
    2011
  • Journal title
    Desalination
  • Record number