• Title of article

    An Integrity Sensor for assessing the performance of low pressure membrane modules in the water industry Original Research Article

  • Author/Authors

    William B. Krantz، نويسنده , , Corliss S. Lin، نويسنده , , Priscilla Ching Yee Sin، نويسنده , , Adrian Yeo، نويسنده , , Anthony G. Fane، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    6
  • From page
    117
  • To page
    122
  • Abstract
    There is a need for a low cost, sensitive, on-line sensor to assess the integrity of membrane modules used in the water industry for water treatment, membrane bioreactors and for pre-treatment prior to using nanofiltration or reverse osmosis. A sensor addressing this need is described whose operating principle is based on measuring the differential pressure across a membrane that intercepts a portion of the permeate from the pre-treatment module(s) relative to the differential pressure across a valve. The latter can be adjusted to maximize the sensitivity of the instrument. A dimensionless metric based on the differential pressures is defined and corroborated with the Silt Density Index. The sensitivity of this Integrity Sensor is demonstrated by its response to cutting one fiber in a UF pre-treatment module that contains 1500 hollow fibers.
  • Keywords
    Low pressure membranes , Membrane integrity monitoring , Microfiltration , Ultrafiltration , Pre-filtration
  • Journal title
    Desalination
  • Serial Year
    2011
  • Journal title
    Desalination
  • Record number

    1115047