• Title of article

    The application of the Bacterial Regrowth Potential method and Flow Cytometry for biofouling detection at the Penneshaw Desalination Plant in South Australia Original Research Article

  • Author/Authors

    Mike B. Dixon، نويسنده , , Teresa Qiu، نويسنده , , Matthew Blaikie، نويسنده , , Con Pelekani، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    8
  • From page
    245
  • To page
    252
  • Abstract
    As the use of reverse osmosis (RO) for sea water desalination is rapidly expanding in Australia, the detection of biofouling on spiral wound RO membranes is becoming increasingly important for limiting this phenomenon and thus making substantial energy savings. Bacterial Regrowth Potential (BRP) and Flow Cytometry (FCM) were assessed as methods for detecting biofouling rapidly and without need for sacrificing any elements for autopsy. The study was undertaken at the Penneshaw Desalination Plant in South Australia from May 2008 to January 2009. Whilst BRP or FCM alone made interpretation of results difficult, the combination of BRP and FCM analysis provided a potential tool to evaluate membrane biofouling. Biofouling of the RO membrane was present but the extent varied due to feed seawater quality and water temperature. The dynamics of biofilms are complex as adhesion and sloughing of bacteria occur simultaneously. The combination of BRP and FCM techniques revealed sloughing or adhesion of bacteria to the membrane surface.
  • Keywords
    Biofouling , flow cytometry , Bacterial Regrowth Potential , Reverse osmosis
  • Journal title
    Desalination
  • Serial Year
    2012
  • Journal title
    Desalination
  • Record number

    1115095