  • Abstract
    In the framework of “Biology and Physics in Space” project of the European Space Agency (ESA), a returning satellite, Foton-M2, carried an open-to-space sample holder outside of the satellite body, called as BIOPAN-5, loaded with exo-biological experiments and dosemeters for RAdiation DOsimetry (RADO). One of the RADO experiments (Teflon – TLD) was dedicated to dose distribution measurements of the cosmic radiation by thermo-luminescent (TL) technique. It was found that the maximum surface absorbed dose rate, averaged over the first ∼8 mg/cm2 thickness, was ∼2 Gy/d and showed a location dependence due the shading effect of the satellite construction elements. The dose rate decreased nearly by 3 orders of magnitude below 500 mg/cm2.
  • Keywords
    Foton-M2 , TL dosimetry , Biopan , Space dosimetry