Title of article
Optimal noise control in a carpentry plant
Author/Authors
Esko Sorainen، نويسنده , , Harri Kokkola، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
7
From page
37
To page
43
Abstract
In this study, the room acoustics program ODEON was applied for the noise control of a carpentry plant. Utilizing the program, a certain amount of mineral wool was installed optimally on the ceiling and walls of the plant. In addition, one moulding plane was enclosed. The measured sound power insulation of the enclosure was 20 dB(A). The reduction of the noise levels in the plant were predicted applying the ODEON program. The predicted average reduction was 5 dB(A). The predicted sound pressure levels were compared to the measured levels. The measured sound pressure levels after the noise control measures differed 1 dB(A) on average from the predicted levels.
Keywords
Woodworking , ODEON , noise control , Carpentry
Journal title
Applied Acoustics
Serial Year
2000
Journal title
Applied Acoustics
Record number
1170356
Link To Document