Title of article
Experimental results on V-M type pulse tube refrigerator Original Research Article
Author/Authors
Wei Dai، نويسنده , , Yoichi Matsubara، نويسنده , , Hisayasu Kobayashi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
5
From page
433
To page
437
Abstract
This article mainly introduces experimental results on a new type pulse tube refrigerator named as V-M type pulse tube refrigerator. The main difference from Stirling type or G-M type pulse tube refrigerator is that thermal compressor similar to that of a V-M cryocooler is used instead of mechanical compressor. By using temperature difference between room temperature and liquid nitrogen, pressure wave with high to low pressure ratio around 1.2 is obtained. This pressure wave is used to generate cooling effect at the cold end. With a 20 K pre-cooler, this machine reaches lowest temperature 5.25 K by using helium4 at 0.77 Hz, 19 bar charge pressure. DC flow plays an important role in our system. It not only influences the final obtainable lowest temperature, but also is used to increase cold end cool-down speed. Total volume of the V-M type pulse tube refrigerator is around 3.3 l. However, dead volume inside rotor housing occupies about 2.8 l and can be much reduced.
Keywords
V-M cryocooler , Expander , DC flow , Pulse tube refrigerator , Displacer