Title of article
Measurement of cryogenic regenerator characteristics under oscillating flow and pulsating pressure Original Research Article
Author/Authors
Kwanwoo Nam، نويسنده , , Sangkwon Jeong، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
7
From page
575
To page
581
Abstract
This paper describes an experimental apparatus developed to investigate detailed thermal and hydrodynamic characteristics of a regenerator at cryogenic temperature under oscillating flow and pulsating pressure conditions. Cold-end of the regenerator is maintained at approximately 85 K for G-M cryocooler type and 100 K for Stirling cryocooler type operations by means of two cryogenic heat exchangers. At both ends of the regenerator, fine hot wire probes are installed to measure the fast oscillating gas temperature and mass flow rate. The gas temperature sensors installed very close to the ends of the regenerator matrix assure precise gas temperature measurement in the regenerator. In this study, thermal and hydrodynamic behaviors of the well-defined wire-screen regenerator are fully characterized. First, pressure drop characteristics are discussed for different frequencies under room temperature. Second, ineffectiveness of the regenerator is obtained for different cold-end temperatures.
Keywords
Ineffectiveness , Regenerator , Pressure drop , Oscillating flow