• Title of article

    Quench detection method without a central voltage tap by calculating active power Original Research Article

  • Author/Authors

    N. Nanato، نويسنده , , K. Nakamura، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    5
  • From page
    1
  • To page
    5
  • Abstract
    In this paper, we present an electric quench detection method without a central voltage tap which may cause the short-circuit of the lead-wires from the voltage taps in the quench detection of a large AC superconducting coil. In this method, an inductive voltage detection coil is used instead of the central voltage tap. The inductive voltage detection coil is electrically insulated from a superconducting coil and therefore the lead-wires do not break down. Through the quench detection tests for a Bi-2223/Ag HTS coil, we show the feasibility of the proposed method for detecting the quench of the large AC superconducting coil.
  • Keywords
    AC superconducting coil , Quench detection , Inductive voltage detection
  • Journal title
    Cryogenics
  • Serial Year
    2004
  • Journal title
    Cryogenics
  • Record number