Title of article
New rotary valves for pulse-tube refrigerators Original Research Article
Author/Authors
M.E. Will، نويسنده , , I.A Tanaeva، نويسنده , , R. Li، نويسنده , , A.T.A.M de Waele، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
8
From page
793
To page
800
Abstract
In most used rotary valves in GM-type pulse-tube refrigerators the rotor makes heavy mechanical contact with the stator, so the valve is liable to wear, and large torques are needed. In this paper we will describe two types of valves, which have balanced forces on the rotor. In the first valve the rotor and the stator make no mechanical contact. The second type is a contact valve, like the classical valves, but the forces on the rotor are balanced in a different way. Therefore, these valves are less liable to wear, and the torques needed to rotate the valves are small.
Keywords
Rotary valves , Pulse tubes , Cryocoolers
Journal title
Cryogenics
Serial Year
2004
Journal title
Cryogenics
Record number
1172493