• Title of article

    Thermal conductivity of subcooled liquid oxygen Original Research Article

  • Author/Authors

    D. Celik، نويسنده , , S.W. Van Sciver، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    6
  • From page
    620
  • To page
    625
  • Abstract
    The thermal conductivity of liquid oxygen below 80 K and pressures up to 1 MPa has been measured using a horizontal, guarded, flat-plate calorimeter. The working equation of the calorimeter is based on the one-dimensional Fourier’s law. The gap between the calorimeter plates was measured in situ from a capacitance measurement. The cooling power to the calorimeter is provided by a two-stage Gifford–McMahan cryocooler. The absolute temperatures are measured using platinum resistance thermometers. The results are compared to existing data and analytical models.
  • Keywords
    Oxygen (B) , Thermal conductivity (C) , Calorimeters (D)
  • Journal title
    Cryogenics
  • Serial Year
    2005
  • Journal title
    Cryogenics
  • Record number