Title of article
Investigation of oscillating flow friction factor for cryocooler regenerator considering cryogenic temperature effect Original Research Article
Author/Authors
Kwanwoo Nam، نويسنده , , Sangkwon Jeong، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
6
From page
733
To page
738
Abstract
In this paper, experimental results and correlations on the friction factor of screen regenerators are presented, being focused on the effect of cryogenic temperature. Cryogenic environment of helium gas is simulated by performing a simple room-temperature experiment using a higher density gas. Based on the experimental results, the proper correlations are proposed with several non-dimensional parameters. Numerical simulation results from the model with the proposed friction factor are compared to the experimental data under actual operating condition of cryocoolers. The experimental data confirm the accuracy and the availability of the proposed friction factor.
Keywords
Oscillating flow , Regenerator , Cryogenic temperature , Friction factor
Journal title
Cryogenics
Serial Year
2005
Journal title
Cryogenics
Record number
1172598
Link To Document