• Title of article

    Analytical treatment of counterflow pulse-tube refrigerators Original Research Article

  • Author/Authors

    M.E. Will، نويسنده , , A.T.A.M de Waele، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    11
  • From page
    421
  • To page
    431
  • Abstract
    In our laboratory we work an a new type of pulse-tube refrigerator. A complete set of relations is derived for the operation of counterflow pulse-tube refrigerators. The input parameters depend on the working fluid, the geometries of the pulse tube and the counterflow heat exchanger, and the compressor characteristics. The calculated molar flow in the heat exchanger agree within 5% with the measured value. The calculated and experimental lowest temperature and the temperature difference between the hot and cold gas in the heat exchanger agree within 10%. This larger difference is caused by difference between the modelled and real heat exchanger.
  • Keywords
    Pulse tube (E) , Thermodynamics (C) , Heat exchangers (E)
  • Journal title
    Cryogenics
  • Serial Year
    2006
  • Journal title
    Cryogenics
  • Record number