• Title of article

    Effect of different treatments of copper surface on its total hemispherical absorptivity bellow 77 K Original Research Article

  • Author/Authors

    V. Musilova، نويسنده , , T. Kralik، نويسنده , , P. Hanzelka، نويسنده , , A. Srnka، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    257
  • To page
    261
  • Abstract
    Total hemispherical absorptivity of copper surfaces treated with standard industrial methods was measured in dependence on the temperature of thermal radiation, varying from 25 K to 300 K. The sample temperature was typically from 5 K to 40 K and did not exceed 70 K. Usability of chemical and mechanical Cu surface finishing as well as Cu plating with Ni and Au for cryogenic design is discussed. As an example of practical application of our results, the cryogenic design of a LN2 trap is presented.
  • Keywords
    Metals (A) , Radiant properties (C) , Heat Transfer (C) , Cryostats (F) , Structural materials (A)
  • Journal title
    Cryogenics
  • Serial Year
    2007
  • Journal title
    Cryogenics
  • Record number