Title of article
A single-stage GM-type pulse tube cryocooler operating at 10.6 K Original Research Article
Author/Authors
Z.H Gan، نويسنده , , W.Q. Dong، نويسنده , , L.M. Qiu، نويسنده , , X.B. Zhang، نويسنده , , H. Sun، نويسنده , , Y.L. He، نويسنده , , R. Radebaugh and G. B. Chen ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
4
From page
198
To page
201
Abstract
In order to explore the lowest attainable refrigeration temperature and improve cooling performance at temperatures around 20 K for a single-stage G–M type pulse tube cryocooler (PTC), numerical and experimental studies were performed. The National Institute of Standards and Technology (NIST) numerical model known as REGEN was applied to the simulation of a G–M type PTC for the first time. Based on the calculation results, a single-stage G–M type PTC was designed, fabricated and tested. The performance improvement of the regenerator in the temperature range of 10–80 K was investigated. The calculations predicted a lowest temperature of 10 K. A lowest temperature of 10.6 K was achieved experimentally with an input power of 7.5 kW, which is the lowest temperature ever achieved by a single-stage PTC. Further more, the cryocooler can provide a cooling power of 20 W at 20.6 K and 39.5 W at 30 K, respectively.
Keywords
Pulse tube cryocooler , Regenerator , REGEN
Journal title
Cryogenics
Serial Year
2009
Journal title
Cryogenics
Record number
1172913
Link To Document