• Title of article

    A two-stage Stirling-type pulse tube cryocooler with a cold inertance tube

  • Author/Authors

    Z.H Gan، نويسنده , , B.Y. Fan، نويسنده , , Y.Z. Wu، نويسنده , , L.M. Qiu، نويسنده , , X.J. Zhang، نويسنده , , G.B. Chen، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    6
  • From page
    426
  • To page
    431
  • Abstract
    A thermally coupled two-stage Stirling-type pulse tube cryocooler (PTC) with inertance tubes as phase shifters has been designed, manufactured and tested. In order to obtain a larger phase shift at the low acoustic power of about 2.0 W, a cold inertance tube as well as a cold reservoir for the second stage, precooled by the cold end of the first stage, was introduced into the system. The transmission line model was used to calculate the phase shift produced by the cold inertance tube. Effect of regenerator material, geometry and charging pressure on the performance of the second stage of the two-stage PTC was investigated based on the well known regenerator model REGEN. Experimental results of the two-stage PTC were carried out with an emphasis on the performance of the second stage. A lowest cooling temperature of 23.7 K and 0.50 W at 33.9 K were obtained with an input electric power of 150.0 W and an operating frequency of 40 Hz.
  • Keywords
    Pulse tube refrigeration , REGEN3.2 , Regenerator , Cold inertance tube , High frequency
  • Journal title
    Cryogenics
  • Serial Year
    2010
  • Journal title
    Cryogenics
  • Record number