Title of article
Measurement of intrinsic material damping using differential calorimetry on specimens under uniaxial tension
Author/Authors
J ?berg، نويسنده , , B Widell، نويسنده , , T Bergstr?m، نويسنده , , H Fredriksson، نويسنده ,
Issue Information
دوهفته نامه با شماره پیاپی سال 2004
Pages
7
From page
125
To page
131
Abstract
A method has been developed to measure the intrinsic damping capacity of metals. A specimen is subjected to a cyclic uniaxial stress, to give a prescribed energy input. The amount of energy that is stored in the specimen is measured using differential calorimetry, i.e. the difference in temperature between the specimen under stress and a non-stressed reference sample is measured. The experiments were performed in an insulated vacuum container to reduce convective losses. The heating rate, together with the energy input, is used as a measure of the intrinsic material damping in the specimen. The method has been developed by testing an aluminium based and a stainless steel alloy. It is possible to distinguish the difference in damping between these two alloys.
Keywords
Material properties , Calorimetric methods , Damping , Intrinsic
Journal title
Thermochimica Acta
Serial Year
2004
Journal title
Thermochimica Acta
Record number
1196259
Link To Document