    Influence of bathroom ventilation rates and toilet location on odor removal

  • Author/Authors

    Yun-Chun Tung، نويسنده , , Shih-Cheng Hu، نويسنده , , Tung-Yi Tsai، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    1810
  • To page
    1817
  • Abstract
    This paper presents an experimental model of odor dispersion from a toilet in a mock-up bathroom. A bathtub, a sink, and a toilet were arranged in the bathroom. A hypothetical odor (SF6 tracer gas) was emitted from a person sitting on the toilet in the bathroom. A new negative pressure wall-exhaust ventilation system, different from a traditional ceiling-exhaust system, was employed in the bathroom. The impacts of ventilation rates of 6.5, 8.5, 17, and 24 ACH (air changes per hour) and the location of the toilet on the concentration distribution of repugnant odors in the bathroom were evaluated. Local air quality index, QI, and odor removal efficiency, ORE, were introduced to evaluate the effectiveness of odor removal in the bathroom. Based on the results of our experiment, a quantitative assessment of odor removal in the bathroom is addressed in this paper.
  • Keywords
    Bathroom , ventilation , Experiment , Odor