Title of article
In vitro study on the steady flow characteristics of proximal anastomotic models
Author/Authors
Leok Poh Chua، نويسنده , , Wenfa Ji، نويسنده , , Tongming Zhou، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
9
From page
464
To page
472
Abstract
A two-dimensional particle image velocimetry (PIV) system is used to study the effects of grafting angle, graft Reynolds number and graft resistance on the steady flow characteristics of proximal anastomosis. Low-velocity regions are found at the heel and toe, whose size depends on the Reynolds number, anastomosis angle and resistance of the graft. Stagnation point is found along the graft outer wall. The spatial gradients of wall shear stress are high around the anastomosis joint. Based on the experimental results, the method of improving the graft patency rate is proposed. The experimental results are in reasonably good agreement with those of previous numerical simulation.
Keywords
Particle image-velocity (PIV) , In vitro study , Proximal anastomosis
Journal title
International Communications in Heat and Mass Transfer
Serial Year
2005
Journal title
International Communications in Heat and Mass Transfer
Record number
1219249