Title of article
The performance simulation of all-glass vacuum tubes with coaxial fluid conduit
Author/Authors
Jeong Tai Kim، نويسنده , , Hyun Tae Ahn، نويسنده , , Hyunjoo Han، نويسنده , , Hyung Taek Kim، نويسنده , , Wongee Chun، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
11
From page
587
To page
597
Abstract
A numerical investigation has been carried out for a solar system, which consists of all-glass (double skin) solar vacuum tubes. Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. Results show good agreement when compared with other experimental data demonstrating the reliability of the present model. The one-dimensional numerical model could be used efficiently in designing all-glass solar collector tubes with different geometrical parameters other than those considered in the present analysis.
Keywords
Analytical approach , one-dimensional , Solar tubular collectors , Coaxial conduit
Journal title
International Communications in Heat and Mass Transfer
Serial Year
2007
Journal title
International Communications in Heat and Mass Transfer
Record number
1220197
Link To Document