• Title of article

    Effects of outlet vent arrangement on air traps in stacked-chip scale package encapsulation

  • Author/Authors

    D. Ramdan، نويسنده , , M.Z. Abdullah، نويسنده , , N.M. Yusop، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    9
  • From page
    405
  • To page
    413
  • Abstract
    The current paper analyzes the effect of outlet vent arrangements on the air traps and pressure distribution of a stacked-chip scale package (S-CSP) during encapsulation. A three-dimensional model of S-CSP is created using GAMBIT and analyzed using FLUENT code. In the molding process, the epoxy molding compound flow behavior calculated using the Castro–Macosko viscosity model by considering the curing effect, and the volume of fluid technique are applied for flow front tracking. The viscosity model is written in C language and compiled using User-Defined Function in FLUENT code. Three different types of outlet vent arrangement are considered in the analysis, namely, Type A, Type B, and Type C. Type A, which has the minimum outlet vent area, shows the minimum air trap and the highest average pressure distribution. The simulation results of the flow front profiles agree well with previous experimental results.
  • Keywords
    Volume of Fluid (VOF) , Curing kinetic model , Epoxy molding compound (EMC) , Castro–Macosko model
  • Journal title
    International Communications in Heat and Mass Transfer
  • Serial Year
    2012
  • Journal title
    International Communications in Heat and Mass Transfer
  • Record number