Title of article
Measurements of the velocity field of the flue gas flow in an electrostatic precipitator model using PIV method
Author/Authors
Jerzy Mizeraczyk، نويسنده , , Marek Kocik، نويسنده , , Jaros?aw Dekowski، نويسنده , , Miros?aw Dors، نويسنده , , Janusz Podli?ski، نويسنده , , Toshikazu Ohkubo، نويسنده , , Seiji Kanazawa، نويسنده , , Toshiyuki Kawasaki، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
6
From page
272
To page
277
Abstract
In this paper, results of use of the PIV method to measure the flow field in a wire-plate type ESP model are presented. The results show that the PIV method is well suited to investigate the flow field in ESP models, in particular the characteristics of secondary and reversal flows, which increase the flow turbulence. The PIV investigation of the near-collecting electrode region shows the importance of the secondary flows, the velocity of which is several tens of cm/s. This means that the secondary flows can have a great impact on the motion and precipitation of small particles, mainly those in the submicron range.
Keywords
Electrostaticprecipitator , Flowvisualization , EHDflow , Flowvelocityfield , Coronadischarge , PIVmethod
Journal title
JOURNAL OF ELECTROSTATICS
Serial Year
2001
Journal title
JOURNAL OF ELECTROSTATICS
Record number
1264323
Link To Document