Title of article
Effectiveness of indoor air cleaning with corona ionizers
Author/Authors
Zygmunt Grabarczyk، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
6
From page
278
To page
283
Abstract
The paper presents an experimental evaluation of the effectiveness of indoor air cleaning from dust particles from the 0.3 to 2.5 μm size range with corona ionizers. Dust particle concentration was measured in a 50-m3 unoccupied office room. Local ionization (portable ionizer: 3 electrodes, −6 kV) of the air inhaled by the phantom and whole room air ionization (net of electrodes hung beneath the ceiling) were tested. Particle concentration was measured with a laser counter Microair 5230 (HIAC-ROYCO). After 2 h of whole room ionization (“ion shower”) particle concentration was reduced by up to two orders of magnitude. Local ionization reduced the dust concentration in inhaled air by several percent.
Keywords
Airions , Electrostaticprecipitation , Indoorair , Airquality