• Title of article

    X-ray Attenuation Coefficients using Polychromatic X-ray Imaging of Pecan Components

  • Author/Authors

    Nachiket Kotwaliwale، نويسنده , , Paul R. Weckler، نويسنده , , Gerald H. Brusewitz، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    8
  • From page
    199
  • To page
    206
  • Abstract
    Digital X-ray imaging has very good potential for non-destructive quality evaluation of intact pecans. Information extracted from X-ray images requires knowledge of the X-ray attenuation properties of the individual components of pecans, viz. nutmeat and shell. Linear attenuation coefficients of pecan components were determined from digital X-ray images taken under polychromatic X-ray beam. Attenuation coefficient varied with X-ray tube peak voltage and sample thickness. Regression models with a value for the coefficient of determination R2 of more than 0·9 were developed to predict attenuation coefficient of pecan nutmeat at a given voltage and nutmeat thickness. The linear attenuation coefficient of pecan shell was higher than that of nutmeat.
  • Journal title
    Biosystems Engineering
  • Serial Year
    2006
  • Journal title
    Biosystems Engineering
  • Record number

    1266816