Title of article
Relative humidity errors when measuring dry and wet bulb temperatures
Author/Authors
A. Ustymczuk، نويسنده , , S.A. Giner، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
106
To page
111
Abstract
Relative humidity (hr) errors, implied in the psychrometric method of measurement, were calculated as a function of the accuracies in temperature sensors, regardless of their origin. An error propagation formula was used which included partial derivatives of hr with respect to dry (Ta) and wet (Twb) bulb temperatures. Relative humidity errors (Ehr) were predicted for Ta between 5 and 35 °C, percentage hr from 30 to 99% and atmospheric pressures from 0.6 x 105 to 1 × 105 Pa. Sensor accuracies from 0.1 to 1 °C were considered. The latter value, when occurring simultaneously in both sensors, led to an Ehr value as large as 9% (in percentage relative humidity units). For dry bulb temperatures varying from 15 to 25 °C and percentage hr from 50 to 80%, a sensor accuracy of 0.2 °C in dry and wet bulb temperature sensors led to Ehr at or below 2%. Inexpensive temperature sensors with accuracies higher than 0.5 °C lead to unacceptably high errors in relative humidity.
Values of Ehr increase linearly with the increase in relative humidity and decrease exponentially with the increase in dry bulb temperature. The reduction of atmospheric pressure causes a very slight linear decrease in the relative humidity errors.
Journal title
Biosystems Engineering
Serial Year
2011
Journal title
Biosystems Engineering
Record number
1267693
Link To Document