    مقايسه ي استحكام باند برشي كامپوزيت به MTA و گلاس آينومر

  • Author/Authors

    Kianimanesh ، N نويسنده Dept. of Operative Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran , , Motamedi ، M نويسنده Dept. of Operative Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran , , Alavi، AA نويسنده Biomaterial Research Center, Dept. of Operative Dentistry, School of Dentistry, Shiraz Uni-versity of Medical Sciences, Shiraz, Iran , , Mohammadi Khoshroo ، N نويسنده Specialist in Operative Dentistry ,

  • Issue Information
    فصلنامه با شماره پیاپی 26 سال 1389
  • Pages
    8
  • From page
    41
  • To page
    48
  • Abstract
    بيان مساله: امروزه مينرال تروكسيد اگرگيت يا MTA (Mineral Trioxide Aggregate) به دليل خصوصيات مطلوبش كاربردهاي باليني گوناگوني پيدا كرده است. در بسياري موارد دندان هايي كه تحت درمان با MTA‌ قرار مي گيرند نيازمند ترميم و بازسازي نهايي هستند، كه كامپوزيت انتخاب مناسبي براي آن به شمار مي رود. در اين موارد باند ميان كامپوزيت و MTA نقشي مهم در گير و مهر و موم ترميم دارد. هدف: هدف از اين پژوهش، بررسي تعيين استحكام باند برشي كامپوزيت به MTA در مقايسه با باند كامپوزيت به گلاس آينومر اصلاح شده با رزين بود. مواد و روش: در اين بررسي آزمايشگاهي خارج دهاني، 60 نمونه در 3 گروه 20 تايي از MTA سفيد و MTA‌ خاكستري و گلاس آينومر فراهم گرديد. سطح 10 نمونه از هر گروه جهت بررسي اثر اچينگ توسط اسيد فسفريك 37 درصد اچ گرديد و 10 نمونه ديگر اچ نشده برجا ماند. همه ي نمونه ها به كامپوزيت Z100 باند شد و استحكام باند برشي آن ها توسط دستگاه آزمون مكانيكي اينسترون تعيين گرديد. همچنين، سطوح شكست نمونه ها با استفاده از استريوميكروسكوپ با بزرگنمايي 10 برابر بررسي شد. نتايج به دست آمده با آزمون هاي آماري آنوا (ANOVA) و توكي (Tukey HSD) واكاوي گرديدند. يافته ها: بيشترين ميزان استحكام باند برشي در زير گروه گلاس آينومر نوري اچ نشده بود و ميان استحكام باند برشي كامپوزيت به گلاس آينومر اچ نشده با 5 زير گروه ديگر اختلاف آماري معناداري ديده شد (001/0 p < ) در ميزان استحكام باند برشي كامپوزيت به MTA سفيد اچ شده و اچ نشده، MTA خاكستري اچ شده و اچ نشده و گلاس آينومر اچ شده اختلاف آماري معنادار گزارش نشد (05/0 > p). نتيجه گيري: استحكام باند برشي كامپوزيت به MTA در حد استحكام باند برشي گلاس آينومر نوري اچ شده به كامپوزيت است. اچ شدن سطح گلاس آينومر نوري استحكام باند آن را به كامپوزيت به گونه ي چشمگيري كاهش مي دهد اما اثري بر استحكام باند برشي MTA به كامپوزيت ندارد. واژگان كليدي: MTA، گلاس آينومر، استحكام باند برشي، كامپوزيت
  • Abstract
    Statement of Problem: Nowadays, MTA has numerous clinical applications because of desirable properties. Many teeth which are treated by MTA need final composite restorations. In this situation, the bonding between composite and MTA has the main role in retention, durability and seal of the restoration. Purpose: Evaluation of the bond strength between MTA and composite resin and its comparison with Resin Modified Glass Ionomer (RMGI). Materials and Method: Sixty specimens were prepared for three experimental groups of white MTA, gray MTA, and glass ionomer Fuji II LC. Ten specimens in each group were etched with 37% phosphoric acid for evaluation of the etching effect while ten specimens were not etched. All specimens were then bonded to the composite and shear bond strength test was performed, using Instron testing machine. In addition, the fractured surfaces of the samples were checked with steriomicroscope (x10). Data were analyzed by ANOVA and Tukey HSD test. Results: The highest shear bond strength value was seen in unetched glass ionomer subgroup and there were significant differences in shear bond strength of the composite to unetched glass ionomer in comparison with the other groups (p < 0.001). There were no significant differences in shear bond strength of the composite to etched and unetched white MTA, etched and unetched gray MTA, and etched glass ionomer ( p > 0.05). Conclusion: Shear bond strength between MTA and the composite is comparable with etched glass ionomer. The etching of the RMGI surface causes a significant decrease of bond strength to the composite but it has no effect on the bond strength of MTA to Composite.
  • Journal title
    Journal of Dentistry :Shiraz University of Medical Sciences
  • Serial Year
    1389
  • Journal title
    Journal of Dentistry :Shiraz University of Medical Sciences
  • Record number

    1332007